Celmore Products

Website Content for Optical Fiber Cables

1. Direct Buried Cable

Cable Construction: Stranded Loose Tube Design
Armoring: Metallic or Non-metallic
Jacketing: Single or Double
Application: Transmission Backbone, Metro Network, CaTV network, Harsh Environment

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652& G.655

Fiber Count

2 to 288

2,4,8,12,18,24,36,48,72,96,144

Max Fibers/Tube

24

2 to 12

No. of Tubes

Customizable as per requirement

1 to 12

Water Blocking

Dry or Gel Filled

Dry Water Blocking

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 3,000 N
Crush Resistance: 2,500 N
Minimum Bending Radius: 10 x Cable OD
Operating Temp: -20 to 80 Degrees Celcius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.20 db/km @ 1550 nm
≤0.22 db/km @ 1625 nm

PMD

≤0.1 ps/√km

≤0.1ps/√km

LowFiber Density Cable- Standard Design

Number of Fibers

6

12

18

24

36

48

No. of Tubes

3

3

3

4

6

6

 

HighFiber Density Cable- Standard Design

Number of Fibers

72

96

144

192

288

No. of Tubes

6

8

12

16

12

 

2. Duct Cable

Cable Construction: Stranded Loose Tube Design
Armoring: Non-metallic
Jacketing: Single
Application: Metro Network, Access Network, CaTV network, Enterprise Network

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652, G.655 & G.657

Fiber Count

2 to 288

2,4,8,12,18,24,36,48,72,96,144

Max Fibers/Tube

24

2 to 12

No. of Tubes

Customizable as per requirement

1 to 12

Water Blocking

Dry or Gel Filled

Dry Water Blocking

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 3,000 N
Crush Resistance: 2,500 N
Minimum Bending Radius: 10 x Cable OD
Operating Temp: -20 to 80 Degrees Celcius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.20 db/km @ 1550 nm
≤0.22 db/km @ 1625 nm

PMD

≤0.1 ps/√km

≤0.1ps/√km

LowFiber Density Cable- Standard Design

Number of Fibers

6

12

18

24

36

48

No. of Tubes

3

3

3

4

6

6

HighFiber Density Cable- Standard Design

Number of Fibers

72

96

144

192

288

No. of Tubes

6

8

12

16

12

 

3. All Dielectric Self Supporting Cable

Cable Construction: Stranded Loose Tube Design
Armoring: Metallic or Non-metallic
Jacketing: Single or Double
Application: High Strength Aerial

Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.655

Fiber Count

2 to 144

2,4,8,12,18,24,36,48,72,96,144

Max Fibers/Tube

24

2 to 12

No. of Tubes

Customizable as per requirement

1 to 12

Water Blocking

Dry or Gel Filled

Dry Water Blocking

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 3,000 N
Crush Resistance: 2,500 N
Minimum Bending Radius: 10 x Cable OD
Operating Temp: -20 to 80 Degrees Celcius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.20 db/km @ 1550 nm
≤0.22 db/km @ 1625 nm

PMD

≤0.1 ps/√km

≤0.1ps/√km

LowFiber Density Cable- Standard Design

Number of Fibers

12

24

48

No. of Tubes

3

4

6

HighFiber Density Cable- Standard Design

Number of Fibers

96

144

No. of Tubes

8

12

 

4. Central Loose Tube Cable

Cable Construction: Uni Tube Construction Central Loose Tube (CLT) Design
Armoring: Metallic or Non-metallic
Jacketing: Single or Double
Application: Access Network, Customer Drop, Emergency restore

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.655

Fiber Count

2 to 24

2,4,8,12,18,24,36,48,72,96,144

Water Blocking

Dry

Dry Water Blocking Yarn

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 1,200 N – 2,000N
Crush Resistance: 2,000 N
Minimum Bending Radius: 10 x Cable OD
Operating Temp: -20 to 80 Degrees Celcius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.20 db/km @ 1550 nm
≤0.22 db/km @ 1625 nm

PMD

≤0.2ps/√km

≤0.2 ps/√km

 

5. Figure 8 Aerial Cable

Cable Construction: Stranded Loose Tube or Central Loose Tube Design
Armoring: Armored or Unarmored
Jacketing: Single or Double
Application: Aerial

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.655

Fiber Count

2 to 144

2,4,8,12,18,24,36,48,72,96,144

Max Fibers/Tube

12

2 to 12

No. of Tubes

Customizable as per requirement

1 to 12

Fiber Count (CLT)

2 to 24

2 to 12

Water Blocking

Dry or Gel Filled

Dry Water Blocking

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 4,000 N
Crush Resistance: 2,500 N
Minimum Bending Radius: 10 x Cable OD
Operating Temp: -20 to 80 Degrees Celsius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.20 db/km @ 1550 nm
≤0.22 db/km @ 1625 nm

PMD

≤0.1 ps/√km

≤0.1ps/√km

LowFiber Density Cable- Standard Design

Number of Fibers

12

24

48

No. of Tubes

3

6

6

 

6. Drop Cable

Cable Construction: Flat Unitube design
Armoring: Unarmoured
Jacketing: Single
Application: Customer Drop

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.657

Fiber Count

2 to 12

2,4,8,12

Water Blocking

Dry

Water Swellable Yarn

Mechancial and Environmental Characteristics

As per requirement

Installation Load: Upto 2,400 N
Operating load: Upto 850 N
Bending Radius: Upto 100 mm
Crush Resistance: Upto 90 N/cm
Operating Temp: -10 to 70 Degrees Celcius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.21 db/km @ 1550 nm

PMD

≤0.2 ps/√km

≤0.2 ps/√km

 

7. Riser Optical Fiber Cable (Indoor/Outdoor)

Cable Construction: Flat Design
Armoring: Unarmoured
Jacketing: LSZH/HDPE
Application: Indoor/Outdoor

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

Tight Buffered

G.652 &G.657

Max. Fiber

As per requirement

2,4,8,16,24

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 700 N
Crush Resistance: 1000 N/10cm
Minimum Bending Radius: 20D
Operating Temp: -10 to 70 Degrees Celsius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.21 db/km @ 1550 nm

 

8. Riser Optical Fiber Cable (Indoor/Outdoor)

General Specifications
Parameter Value

Material

High / Medium Density Polyethylene

Applications

Telcos, Water Supply, Sui-Gas Construction Firms,
Chemical Industry, Sprinkler irrigation systems & Farming

Colour

As per requirement

Size

As per requirement

Outer Surface

Smooth and Circular

Inner Surface

Smooth and Soft

Coils

100 – 250m (or as per requirement)

In House Testing Facilities

Density Test Melt Flow Index Test Hydrostatic Pressure Test
Tensile Test Elongation Test Impact Test

Marking

As per requirement

 

9. FTTH Outdoor Cable

Cable Construction: Flat Design
Armoring: Unarmoured
Jacketing: LSZH/HDPE
Application: Outdoor

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.657

Max. Fiber

As per requirement

2 to 12

Self Supporting Member

As per requirement

Steel Wire / FRP CSM 1 mm

Strength Member

As per requirement

Steel Wire / FRP CSM 0.5mm

Water Blocking

Dry

Water Swellable Yarn

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 6000 N
Crush Resistance: 1000 N/10cm
Minimum Bending Radius: 20D
Operating Temp: -10 to 70 Degrees Celsius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.21 db/km @ 1550nm

 

10. FTTH Indoor Cable

Cable Construction: Flat Design
Armoring: Unarmoured
Jacketing: LSZH/HDPE
Application: Indoor

General Specifications
Parameter Value Standard Cable Specs

Fiber Type

As per requirement

G.652 & G.657

Max. Fiber

As per requirement

2, 4

Strength Member

As per requirement

Steel Wire / FRP CSM 0.5mm

Water Blocking

Dry

Water Swellable Yarn

Mechancial and Environmental Characteristics

As per requirement

Tensile Strength: 0 N
Crush Resistance: 1000 N/10cm
Minimum Bending Radius: 20D
Operating Temp: -10 to 70 Degrees Celsius

Average Attenuation

Low loss cables are available

≤0.35 db/km @ 1310nm
≤0.21 db/km @ 1550nm